Mitsubishi Electric GT1685 Connection Manual page 629

Got1000 series
Table of Contents

Advertisement

POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
17.3.1 Setting communication interface
(Communication settings)
Confirming communication state of CRnD-
700
(1) When using the Command Prompt of Windows
Execute a Ping command at the Command Prompt of
®
Windows
.
(a) When normal communication
C:\>Ping 192.168.0.19
Reply from 192.168.0.19: bytes=32 time<1ms
TTL=64
(b) When abnormal communication
C:\>Ping 192.168.0.19
Request timed out.
(2) When abnormal communication
At abnormal communication, check the followings and
execute the Ping command again.
• Cable connecting condition
• Parameter settings
• Operation state of the CRnD-700. (faulty or not)
• The IP address of the CRnD-700 specified for the
Ping command.
®
.
17. ROBOT CONTROLLER CONNECTION
17.4 PLC Side Settings
17
18
19
20
21
22
23
17 - 7