Mitsubishi Electric GT1685 Connection Manual page 281

Got1000 series
Table of Contents

Advertisement

POINT
POINT
POINT
When connecting a GOT to CH2
Set the CH1 side mode switch to any other than "0"
(interlocked operation).
CH1
CH2
MODE
(2) Transmission specifications setting switch
Transmission
Setting
specifications setting
switch
switch
SW01
AJ71QC24(N)
SW02
(-R2/R4)
SW
ON
ON
01
SW03
02
03
04
SW04
05
06
07
SW05
08
SW06
09
10
11
12
SW07
A1SJ71QC24(N)
*1
(N1)(-R2)
SW08
1
2
SW09
3
to
4
SW12
5
6
SW
7
8
9
10
SW13
11
12
to
ON
SW15
*1
The following shows the layout of switches in the case of the
following hardware versions for the module.
Switch settings and switch ON/OFF directions are the same.
CH1/2
1
9
2
10
3
11
4
12
SW
5
6
7
8
ON
Target unit
A1SJ71QC24
A1SJ71QC24-R2
A1SJ71QC24N, A1SJ71QC24N-R2
Set
Description
value
Operation
Independent
OFF
setting
operation
Data bit
8bits
ON
setting
Parity bit
enable/disable
Enable
ON
setting
Even/odd parity
Odd
OFF
setting
Stop bit setting
1bit
OFF
Sum check
enable/disable
Enable
ON
setting
Write during
RUN enable/
Enable
ON
disable setting
Setting change
Disable
OFF
enable/disable
(prohibit)
(Consistent
Transmission
with the GOT
See (a)
speed setting
side
specifications)
The switch is
located on
the left side
of the
All OFF
module.
(only on
AJ71QC24 (-
R2/R4))
Hardware version
Version E hardware or earlier
Version D hardware or earlier
Version A hardware
(a) Transmission speed setting (SW09 to SW12)
Set the transmission speed (SW09 to SW12) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
Transmission speed
Setting
4800
9600
19200
Switch
bps
bps
bps
SW09
OFF
ON
OFF
SW10
OFF
OFF
ON
SW11
ON
ON
ON
SW12
OFF
OFF
OFF
*1
Only transmission speeds available on the GOT side are
shown.
*2
When the software version of AJ71QC24 (-R2/R4) and
A1SJ71QC24 (-R2) is "L" or earlier, and when 2 devices are
connected to the two interfaces individually, make the setting
so that the total transmission speed of the two interfaces is
within 19200bps.
When the total transmission speed of the two interfaces is
within 19200bps, a controller other than GOT can be
connected to the computer link module.
When only one device is connected to either of the
interfaces, a maximum transmission speed of 19200bps can
be set to the one where the device is connected.In this
instance, set SW09 to SW12 to "OFF" on the other side.
*3
When 3 devices are connected to the two interfaces
individually in the case of AJ71QC24N(-R2/R4),
A1SJ71QC24N(-R2), and A1SJ71QC24N1(-R2), make the
setting so that the total transmission speed of the two
interfaces is within 115200bps (within 230400bps in the case
of A1SJ71QC24N1(-R2)).
When the total transmission speed of the two interfaces is
within 115200bps (within 230400bps in the case of
A1SJ71QC24N1(-R2)), a controller other than GOT can be
connected to the computer link module.
When only one device is connected to either of the
interfaces, a maximum transmission speed of 115200bps
can be set to the one where the device is connected.In this
instance, set SW09 to SW12 to "OFF" on the other side.
*4
This can be set only in the case of AJ71QC24N (-R2/R4),
A1SJ71QC24N (-R2) or A1SJ71QC24N1 (-R2).
(3) Station number switch (for both CH1 and CH2)
*5
Station number switch
Set the station number of the
10
1
serial communication module
to which an access is made
STATION
No.
from the GOT.
*5
The station number switch in the figure is for the AJ71QC24
(N) (-R2/R4).
POINT
POINT
POINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
7. COMPUTER LINK CONNECTION
7.5 PLC Side Setting
*1*2*3
38400
57600
115200
*4
*4
*4
bps
bps
bps
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
ON
Set
Contents
value
0
7 - 27
1
2
3
4
5
6
7
8