Accessing By Gx Logviewer - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

23.6.5 Accessing by GX LogViewer

The following shows the procedure to set the FA
transparent function of GX LogViewer.
1.
Click [Show Assistant Dialog] for [View] on GX
LogViewer.
2.
The [Assistant] dialog box is displayed.
3.
Click [LCPU]
[Show Logged Device Status] in the
[Assistant] dialog box.
4.
The [Transfer Setup Connection 1] dialog box is
displayed.
5.
Set the [Transfer Setup Connection 1]:
PC side I/F
PLC side I/F
Other Station Setting
6.
For [PC side I/F Serial Setting] and [PLC side I/F
Detailed Setting of GOT] of [Transfer Setup], refer to
the following.
23.6.4 Accessing by GX Works2
: Serial USB
: GOT
: (Select from the system
configuration)
23.6.6 Accessing PLC by
GX Configurator-QP
The following shows the procedure to set the FA
transparent function of GX Configurator-QP.
1.
Click [Connection setup] for [Online] on GX
Configurator-QP.
2.
The [Connection setup] is displayed.
3.
Set the [PC side] in [Connection setup].
When connecting the GOT and PC with serial
Interface: (RS-232C)
COM setting: COM1 to COM10
Transmission speed: 9.6kbps to 115.2kbps
When connecting the GOT and PC with USB
Interface: USB
23. FA TRANSPARENT FUNCTION
23.6 Personal Computer Side Setting
17
18
19
20
21
22
23
23 - 67