Mitsubishi Electric GT1685 Connection Manual page 732

Got1000 series
Table of Contents

Advertisement

The number of channels and the functions that can be used differ depending on the GOT to be used.
The table below shows the allowable combinations of connection types, the number of channels and restricted
functions.
Item
Allowable combination of connection types
• Bus/network/Ethernet connection: 1 channel
(a)
• Serial connection: 1 to 3 channels
(b)
• Serial connection: 4 channels
*1
When the functions below are used, the connectable number of channels may be restricted depending on the combination of the
functions to be used.
The video display function and RGB display function cannot be used together.
The CF card unit and the CF card extension unit cannot be used at the same time.
For details, refer to the following.
*2
When any of the connection methods below is used, Ethernet connection cannot be used although Ethernet download, gateway
function, MES interface function and file transfer function (FTP client) can be used.
*3
For the FA transparent function via the RS-232 connection, the RS-232 interface built in the GOT is available only.
When the RS-232 interface built in the GOT is already used, the FA transparent function is not available.
(3) GT14
For GT14, the combinations of the Ethernet connection and the serial connection are available as shown in the
following table.
Ethernet connection
CNC connection (Ethernet connection)
Third party PLC connection (Ethernet connection)
Ethernet connection
Microcomputer connection (Ethernet)
MODBUS
Direct CPU connection
Computer link connection
CC-Link connection (via G4)
Serial connection
Inverter connection
Servo amplifier connection
CNC connection (serial connection)
GOT Multi- Drop Connection
22 - 18
22. MULTI-CHANNEL FUNCTION
22.3 GOT Side Settings
Fingerprint authentication
Remote personal computer operation
External I/O function
Hard copy function(for printer output)
Functions with the CF card unit or CF card extension unit
22.3.4 Determining the GOT side interface (Interface selection)
Bus connection
MELSECNET/10 connection
CC-Link connection
Connection type
®
/TCP connection
GOT to be used
GT1595
GT1585
GT155
GT157
GT156
Max. 4
Max. 2
channels
channels
Max. 4
Max. 2
channels
channels
Barcode function
Video display function
RGB display function
Sound output function
MELSECTNET/H connection
CC-Link IE Controller Network connection
®
MODBUS
/TCP connection
8.ETHERNET CONNECTION
18.2.4Ethernet connection
Non-Mitsubishi Electric Products 1
• 3. CONNECTION TO OMRON PLC 3.3 Ethernet Connection
Non-Mitsubishi Electric Products 2
• 6. CONNECTION TO YASKAWA PLC 6.3 Ethernet Connection
• 7. CONNECTION TO YOKOGAWA PLC 7.3 Ethernet Connection
• 10. CONNECTION TO ALLEN-BRADLEY PLC 10.3 Ethernet
Connection
• 14. CONNECTION TO SIEMENS PLC 14.3 Ethernet Connection
Microcomputer, MODBUS Products, Peripherals
• 3. MICROCOMPUTER CONNECTION (ETHERNET)
Microcomputer, MODBUS Products, Peripherals
• 5. MODBUS(R)/TCP CONNECTION
6.DIRECT CONNECTION TO CPU
7.COMPUTER LINK CONNECTION
14.CC-Link CONNECTION (Via G4)
15.INVERTER CONNECTION
16.SERVO AMPLIFIER CONNECTION
18.2.1Direct connection to CPU
20.GOT MULTI-DROP CONNECTION
: Allowed
Functions that are restricted by the connection
*1*2
type
FA transparent function
RS-232
*3
*3
RFID function
Operation panel function
Report function
CC-Link IE Field Network connection
Reference
(Continued to next page)
: Restricted
USB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents