[Controller Setting] of GT Designer3
(1) When MODEL GT15-J61BT13 CC-Link
communication unit is used
Item
Station No.
Transmission Rate
Mode
Expanded Cyclic
Number of stations occupied
Input for Error Station
Retry
Timeout Time
Delay Time
(2) When MODEL GT15-75J61BT13-Z CC-Link
communication unit is used
Item
Retry
Timeout Time
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
13.3.1 Setting communication interface
(Communication settings)
Setting of the CC-Link communication unit
(Only when MODEL GT15-75J61BT13-Z
CC-Link communication unit is used)
Item
Mode setting switch
Station number setting switch
Transmission baudrate setting switch
SW1 (Input data status of the
Condition
data link error station)
setting
SW2 (Number of occupied
switches
stations)
POINT
POINT
POINT
Setting of the CC-Link communication unit
For the setting method of the CC-Link communication
unit, refer to the following.
13.3.3 Switch setting (Only when MODEL
GT15-75J61BT13-Z CC-Link communication
unit is used)
Set value
1: Station No.1
0: Online 156kbps
Ver.1: Remote net (Ver.1 mode)
Single (Use default value)
1 Station
0: Clear
3times (Use default value)
3sec (Use default value)
0ms (Use default value)
Set value (Use default value)
3times
3sec
Set value
0: Online (fixed)
1: Station No.1
0: 156kbps
OFF: Cleared
OFF: 1 station
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4.6 Connecting to CC-Link
module (Q Series) with Ver.2
compatible
This section describes the settings of the GOT and CC-
Link module (Q Series) in the following case of system
configuration.
POINT
POINT
POINT
CC-Link module (Q Series)
For details of the CC-Link module (Q Series), refer to
the following manual.
CC-Link System Master/Local Module User's
Manual QJ61BT11N
System configuration
■ [Communication settings] of GT Designer3
*1
<CC-Link module>
(Use the default value for the settings other than the following.)
Type
: Master station
Station No.
: Station No.0
Mode
: Remote net (Ver.2 mode)
All connect count
: 1
Transmission speed : 156kbps
■ Switch setting of CC-Link module (Q Series)
■ [Network parameter] of GX Developer
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the CC-Link module is set to "70".
13.4 PLC Side Setting
<GOT>
(Use the default value for settings other
than the following.)
Station No.
: Station No.1
Expanded cyclic setting : Single
Number of
: Exclusive station 1
stations occupied
Transmission speed
: 156kbps