Connecting To Ethernet Module (A Series) - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

(3) Communication confirmation
The RDY LED on the Ethernet module turn on when
the module is ready to communicate.
For confirming the communication state, refer to the
following.
8.3.4 ■Confirming the communication state of
Ethernet module
AJ71QE71N3-T, AJ71QE71N-B5,
AJ71QE71N-B2, AJ71QE71N-T,
AJ71QE71N-B5T, AJ71QE71,
AJ71QE71-B5
RUN
BUF1
BUF2
RDY
BUF3
BSY
BUF4
SW.ERR.
BUF5
COM.ERR.
BUF6
CPU R/W
BUF7
BUF8
TEST
TEST ERR.
[Controller Setting] and [Ethernet] of GT
Designer3
(1) Controller setting
Item
GOT NET No.
GOT PLC No.
GOT IP Address
GOT Port No.
(Communication)
GOT Port No.
(Ethernet Download)
Default Gateway
Subnet Mask
Retry
Startup Time
Timeout Time
Delay Time
(2) Ethernet setting
Item
Host
N/W No.
PLC No.
Ethernet
Type
setting No.1
IP address
Port No.
Communication
POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For
[Controller
Setting]
Designer3, refer to the following.
8.3.1 Setting communication interface
(Communication settings)
8 - 44
8. ETHERNET CONNECTION
8.4 PLC Side Setting
A1SJ71QE71N3-T, A1SJ71QE71N-B5,
A1SJ71QE71N-B2, A1SJ71QE71N-T,
A1SJ71QE71N-B5T,A1SJ71QE71-B5,
A1SJ71QE71-B2
RUN
BUF1
RDY
BUF2
BSY
BUF3
SW.ERR.
BUF4
COM.ERR.
BUF5
TEST
BUF6
TEST ERR.
BUF7
CPU R/W
BUF8
Set value (Use default value)
1
1
192.168.0.18
5001
5014
0.0.0.0
255.255.255.0
3times
3sec
3sec
0ms
Set value
*
1
2
AJ71QE71
192.168.0.19
5001 (fixed)
UDP (fixed)
and
[Ethernet]
of
8.4.10 Connecting to Ethernet
module (A Series)
This section describes the settings of the GOT and
Ethernet module (A Series) in the following case of the
system configuration.
POINT
POINT
POINT
Ethernet module (A Series)
For details of the Ethernet module (A Series), refer to
the following manual.
For A Ethernet Interface Module User's Manual
System configuration
■ Switch settings of Ethernet module
■ Sequence program
*1
The Ethernet module is mounted on the base unit slot 0.
The Start I/O No. of the Ethernet module is set to "0".
*2
These setting items do not exist at the PLC side. However,
the virtual values must be set on the GOT side.
GT
[Controller Setting] and [Ethernet] of GT
Designer3
<GOT> (The settings other than the
following are set to the default)
Network No.
PLC No.
IP address
Port No.
Communication format : UDP (fixed)
*1
<Ethernet module> (The settings other than the
following are set to the default)
Network No.
: 1 (virtual)
PLC No.
: 2 (virtual)
IP address
: 192.168.0.19
Port No.
: 5001
Communication format
: UDP(fixed)
■ [Controller Setting] and [Ethernet] of GT Designer3
: 1
: 1
: 192.168.0.18
: 5001
*2
*2