(2) Station information setting
*1
Item
Station type
*2
Exclusive station count
Reserve/invalid station
select
Intelligent buffer select
(word)
: Necessary
*1
When the [Mode] of the CC-Link module is set at [Remote
net - (Ver. 1 mode)], [Remote station points] cannot be set.
*2
Set the same setting as that of the GOT.
POINT
POINT
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU,
operate the PLC CPU ether turning OFF and then ON
or resetting.
[Controller Setting] of GT Designer3
Item
Station No.
Transmission Rate
Mode
Expanded Cyclic
Number of stations occupied
Input for Error Station
Retry
Timeout Time
Delay Time
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
13.3.1 Setting communication interface
(Communication settings)
13 - 34
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
Setting
necessity at
Set value
GOT
connection
Intelligent
device station (fixed)
Exclusive station 1
No setting
(Use default value)
: As necessary
: Not necessary
Set value
1: Station No.1
0: Online 156kbps
Ver.1: Remote net (Ver.1 mode)
Single (Use default value)
1 Station
0: Clear
3times (Use default value)
3sec (Use default value)
0ms (Use default value)
13.4.9 Connecting to MELSEC-L
series with CC-Link Ver.2
compatible
This section describes the settings of the GOT and
MELSEC-L in the following case of the system
configuration.
POINT
POINT
POINT
(1) CC-Link module (L Series)
For details of the CC-Link module (L Series), refer
to the following manual.
MELSEC-L CC-Link System Master/Local
Module User's Manual
(2) CC-Link function built-in CPU
For details on the CC-Link function built-in CPU,
refer to the following manual.
MELSEC-L CC-Link System Master/Local
Module User's Manual
System configuration
(Example when using CC-Link module (L Series))
*1
<CC-Link module>
(Use the default value for the settings other than the following.)
Type
: Master station
Station No.
: Station No.0
Mode
: Remote net (Ver.3 mode)
All connect count
: 1
Transmission speed : 156kbps
■ [Network parameter] of GX Developer
■ [Controller Setting] of GT Designer3
<GOT>
(Use the default value for settings other
than the following.)
Station No.
: Station No.1
Expanded cyclic setting : Single
Number of
: Exclusive station
stations occupied
Transmission speed
: 156kbps