Bit 3—Framing Error (FER): Indicates a framing error in the data read from SCFRDR2.
Bit 3: FER
0
1
Bit 2—Parity Error (PER): Indicates a parity error in the data read from SCFRDR2.
Bit 2: PER
0
1
Rev. 4.0, 04/00, page 580 of 850
Description
There is no framing error in the receive data read from SCFRDR2
[Clearing conditions]
Power-on reset or manual reset
When there is no framing error in SCFRDR2 read data
There is a framing error in the receive data read from SCFRDR2
[Setting condition]
When there is a framing error in SCFRDR2 read data
Description
There is no parity error in the receive data read from SCFRDR2
[Clearing conditions]
Power-on reset or manual reset
When there is no parity error in SCFRDR2 read data
There is a parity error in the receive data read from SCFRDR2
[Setting condition]
When there is a parity error in SCFRDR2 read data
(Initial value)
(Initial value)