Second Alarm Register (Rsecar); Minute Alarm Register (Rminar) - Hitachi SH7750 series Hardware Manual

Superh risc engine
Hide thumbs Also See for SH7750 series:
Table of Contents

Advertisement

11.2.9

Second Alarm Register (RSECAR)

RSECAR is an 8-bit readable/writable register used as an alarm register for the RTC's BCD-coded
second value counter, RSECCNT. When the ENB bit is set to 1, the RSECAR value is compared
with the RSECCNT value. Comparison between the counter and the alarm register is performed
for those registers among RSECAR, RMINAR, RHRAR, RWKAR, RDAYAR, and RMONAR in
which the ENB bit is set to 1, and the RCR1 alarm flag is set when the respective values all match.
The setting range is decimal 00 to 59 + ENB bit. The RTC will not operate normally if any other
value is set.
The ENB bit in RSECAR is initialized to 0 by a power-on reset. The other fields in RSECAR are
not initialized by a power-on or manual reset, or in standby mode.
Bit:
Initial value:
R/W:

11.2.10 Minute Alarm Register (RMINAR)

RMINAR is an 8-bit readable/writable register used as an alarm register for the RTC's BCD-
coded minute value counter, RMINCNT. When the ENB bit is set to 1, the RMINAR value is
compared with the RMINCNT value. Comparison between the counter and the alarm register is
performed for those registers among RSECAR, RMINAR, RHRAR, RWKAR, RDAYAR, and
RMONAR in which the ENB bit is set to 1, and the RCR1 alarm flag is set when the respective
values all match.
The setting range is decimal 00 to 59 + ENB bit. The RTC will not operate normally if any other
value is set.
The ENB bit in RMINAR is initialized by a power-on reset. The other fields in RMINAR are not
initialized by a power-on or manual reset, or in standby mode.
Bit:
Initial value:
R/W:
Rev. 4.0, 04/00, page 226 of 850
7
6
ENB
10-second units
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
R/W
R/W
7
6
ENB
10-minute units
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
R/W
R/W
5
4
R/W
R/W
5
4
R/W
R/W
3
2
1-second units
R/W
R/W
3
2
1-minute units
R/W
R/W
1
0
R/W
R/W
1
0
R/W
R/W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh7750sSh7750

Table of Contents