Set Inlinepower Management; Clear Inlinepower Management - Enterasys Matrix DFE-Gold Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

Configuring Power over Ethernet (PoE)
Example
This example shows how to reset the PoE threshold to 75 on module 1:
Matrix(rw)->clear inlinepower threshold 1

set inlinepower management

Use this command to set the PoE management mode on a specified module.
Syntax
set inlinepower management {realtime | class} module-number
Parameters
realtime
class
module‐number
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to set the PoE management mode to "class" on module 1:
Matrix(rw)->set inlinepower management class 1

clear inlinepower management

Use this command to reset the PoE management mode on a specified module back to the default 
setting of "realtime".
Syntax
clear inlinepower management module-number
Parameters
module‐number
Defaults
None.
Mode
Switch command, Read‐Write.
2-68 Startup and General Configuration
Manages power based on the actual power consumption of the ports.
Manages power based on the IEEE 802.3af definition of the class upper 
limit, except classes 0 and 4, for which the actual power consumption is 
used.
Specifies the module on which to set the PoE management mode. 
Specifies the module on which to reset the PoE management mode. 