Configuring Simple Network Time Protocol (SNTP)
Defaults
If offset hours or minutes are not specified, none will be applied.
Mode
Switch command, Read‐Write.
Example
This example shows how to set the time zone to EST with an offset of minus 5 hours:
Matrix(rw)->set timezone ETS -5 0

clear timezone

Use this command to remove SNTP time zone adjustment values.
Syntax
clear timezone
Parameters
None.
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to remove SNTP time zone adjustment values:
Matrix(rw)->clear timezone
13-10 SNTP Configuration