clear config

Parameters
hh:mm 
reason
Defaults
If a reason is not specified, none will be applied.
Mode
Switch command, Read‐Write.
Example
Matrix(rw)‐>reset in 5:20This example shows how to schedule a device reset in 5 hours and 20 
minutes:
Reset scheduled in 5 hours and 20 minutes
Proceed with scheduled reset? (y/n) [n]? y
Reset scheduled for 19:56:01, Wed March 15 2002 (in 5 hours 20 minutes
clear config
Use this command to clear the user‐defined switch and router configuration parameters for one or 
more modules. 
Syntax
clear config mod-num | all
Parameters
mod‐num | all
Defaults
None.
Mode
Read‐Write.
Usage
Executing clear config on one Matrix module resets that module back to its factory defaults. If that 
module is in a chassis with other active modules, it will inherit system settings from the system. 
For a list of factory device default settings, refer to "Factory Default Settings" on page 2‐1.
This command will not affect the IP address.
Example
This example shows how to clear configuration parameters in all modules:
Matrix(rw)->clear config all
Specifies the number of hours and minutes into the future to perform a 
reset.
(Optional) Specifies a reason for the reset
Clears configuration parameters in a specific module or in all modules. 
Enterasys Matrix DFE-Gold Series Configuration Guide 2-97