set inlinepower threshold

Example
This example shows how to display switch PoE properties. In this case, modules in slots 2 and 3 
are PoE modules, so their power configurations display:
B3(su)->show inlinepower
Detection Mode
Total Power Detected
Total Power Available
Total Power Assigned
Power Allocation Mode
Power Trap Status
Power Redundancy Status: not redundant
Power Supply 1 Status
Power Supply 2 Status
Slot
----
2
3
set inlinepower threshold
Use this command to set the PoE usage threshold on a specified unit or module.
Syntax
set inlinepower threshold usage-threshold unit-number
Parameters
threshold value
module‐number
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the PoE threshold to 50 on module/unit 1:
B3(su)->set inlinepower threshold 50 1

set inlinepower trap

Use this command to enable or disable the sending of an SNMP trap message for a unit
whenever the status of its ports changes, or whenever the unit's PoE usage threshold is crossed. 
The unit's PoE usage threshold must be set using the set inlinepower threshold command as 
described on page 3‐32.
3-32 Basic Configuration
: auto
: 400 Watts
: 250 Watts
: 0 Watts
: auto
: enable
: Ok
: Not Installed
Status
Power(W)
------
--------
auto
360
auto
360
Specifies a PoE threshold as a percentage of total system power usage. 
Valid values are 11 to 100. 
Specifies the module on which to set the PoE threshold. 
Consumption(W)
Usage(%)
--------------
--------
0.00
0.00
5.20
1.44
Threshold(%)
Trap
------------
----
80
enable
80
enable
 
or module
 