set inlinepower threshold

Example
This example shows how to display system power properties:
C2(su)->show inlinepower
Detection Mode
Unit
----
1
Table
5‐1 provides an explanation of the command output.
Table 5-1 show inlinepower Output Details
Output
Detection Mode
Unit
Status
Power (W)
Consumption (W)
Usage (%)
Threshold (%)
Trap
set inlinepower threshold
Use this command to set the power usage threshold on a specified unit or module.
Syntax
set inlinepower threshold usage-threshold module-number
Parameters
usage‐threshold
module‐number
Defaults
None.
Mode
Switch command, read‐write.
5-2 Configuring System Power and PoE
: auto
Status
Power(W)
------
--------
auto
480
What It Displays...
Displays the PD detection mode used by the switch. The detection mode can be
configured with the command
Number of PoE-capable module.
Whether the PoE administrative state is off (disabled) or auto (on). This state is not
configurable.
Unit's available power wattage.
Unit's power wattage consumed.
Unit's percentage of total system PoE power usage.
Unit's alloted percentage of total PoE power available in the system. The threshold
can be configured with the command
Whether PoE trap messaging is enabled or disabled on this unit. Trap messaging
can be configured with the command
Specifies a power threshold as a percentage of available system power. 
Valid values are 11 to 100. 
Specifies the module or unit on which to set the power threshold. 
Consumption(W)
Usage(%)
--------------
--------
0.00
0.00
"set inlinepower
"set inlinepower
"set inlinepower
Threshold(%)
Trap
------------
----
80
enable
detectionmode" (page 5-3).
threshold" (page 5-2).
trap" (page 5-3).