Send-Lifetime - Enterasys Matrix DFE-Gold Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

send-lifetime

end‐time
infinite
Defaults
None.
Mode
Router command, Key chain key configuration: Matrix>Router(config‐keychain‐key)#
Usage
The "no" form of this command removes the accept‐lifetime configuration for an authentication 
key.
Examples
This example shows how to allow the "password" authentication key to be received as valid on its 
RIP‐configured interface beginning at 2:30 on November 30, 2002 with no ending time (infinitely):
Matrix>Router(config-router)#key chain md5key
Matrix>Router(config-keychain)#key 3
Matrix>Router(config-keychain-key)#key-string password
Matrix>Router(config-keychain-key)#accept-lifetime 02:30:00 nov 30 2002 infinite
send-lifetime
Use this command to specify the time period during which an authentication key on a key chain is 
valid to be sent.
Syntax
send-lifetime start-time month date year {duration seconds | end-time | infinite}
no send-lifetime [start-time month date year]
Parameters
start‐time
month
date
year
duration seconds
end‐time
infinite
Specifies the hours, minutes and seconds (hh:mm:ss) and the month, date 
and year from the start‐time the key is valid to be received. 
Specifies that the key is valid to be received from the start‐time on.
Specifies the time of day the authentication key will begin to be valid to 
be sent. Valid input is hours:minutes:seconds (hh:mm:ss).
Specifies the month the authentication key will begin to be valid to be 
sent. Valid input is the first three letters of the month.
Specifies the day of the month the authentication key will begin to be 
valid to be sent. Valid values, depending on the length of the month, are 
1 ‐ 31.
Specifies the year the authentication key will begin to be valid to be 
sent. Valid input is four digits up to 2035.
Length of time (in seconds) the key is valid to be sent. Valid values are 1 
‐ 4294967295.
Specifies the hours, minutes and seconds (hh:mm:ss) and the month, date 
and year from the start‐time the key is valid to be sent.
Specifies that the key is valid to be sent from the start‐time on.
Enterasys Matrix DFE-Gold Series Configuration Guide 21-11
Configuring RIP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents