CHAPTER 23 CAN CONTROLLER
■ Completing Reception
RCx of the reception complete register (RCR) becomes "1" after storing the received message.
If a reception interrupt is enabled (RIEx of the reception interrupt enable register (RIER) is "1"), an
interrupt occurs.
Note:
This CAN controller will not receive any messages transmitted by itself.