• (f) The Port Audit and Update Test (#36) failed due to an internal system error. Enter status
access-endpoint extension and verify the status of the port. If the wideband access endpoint
port is out of service, enter release access-endpoint extension to put it back into service. Retry
the test command.
Technician-Demand Tests: Descriptions and
Error Codes
Always investigate tests in the order presented in the table below when inspecting errors in the
system. By clearing error codes associated with the NPE Crosstalk Test, for example, you may also
clear errors generated from other tests in the testing sequence.
Table 88. Technician-Demand Tests
Order of Investigation
NPE Crosstalk Test (#6)
Note: This Test ABORTS with code 1412
when run on a Avaya G700 Media
Gateway system.
Conference Circuit Test (#7)
Note: This Test ABORTS with code 1412
when run on a Avaya G700 Media
Gateway system.

Port Audit and Update Test (#36)

*D = Destructive; ND = Nondestructive
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1-MM Interface Media
Module to ensure that the wideband access endpoint port's translation is correct.
Table 89. TEST #36 Audit and Update Test
Error
Code
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
WAE-PORT (Wideband Access Endpoint Port)
Short Test
Long Test
Sequence
Sequence
X
X
X
X
D/ND*
ND
ND
ND
1 of 2