6 Avaya MultiVantage Software-Controlled Maintenance:
• (b) Rotary dial before wink
sends wink on a wink-start trunk.
1) Verify trunk administered wink/immediate-start parameter.
2) Refer problem to CO .
• (c) Rotary dial too early
on an immediate-start trunk.
1) Verify trunk administered wink/immediate-start parameter.
2) Refer problem to CO .
• (d) Rotary dial pulse during wink
too soon after seizure on a wink-start trunk.
1) Verify trunk administered wink/immediate-start parameter.
2) Refer problem to CO .
• (e) This is a software audit error that does not indicate any hardware malfunction. Run Short Test
Sequence and investigate associated errors (if any).
• (f) This error type indicates that the Media Module has been removed or has been insane for more
than 11 minutes. To clear the error, reinsert or replace the Media Module.
• (g) Rotary dial pulse on-hook longer than 105 msec
1) Test trunk by performing an incoming test call.
2) Refer problem to CO .
• (h) Rotary dial rate below 8 pulses/sec
1) Verify trunk administered interdigit-timing parameters.
2) Refer problem to CO .
• (i) Rotary dial rate above 12 pulses/sec
1) Verify trunk administered interdigit-timing parameters.
2) Refer problem to CO .
• (j) Digit detection
1) Verify trunk administered interdigit timing parameters.
2) Refer problem to CO .
• (k) Loop current active
end drops first and the CO does not release the trunk within 4 minutes.
1) Verify the interface to the network with a hand telephone set. If calls are placed correctly,
then refer problem to the CO .
2) If unable to place calls or this equipment is not available, check the status on port using the
status trunk command. If active but not connected, disconnect bridging clips at the
network interface. Check status on the trunk. If trunk went idle, then replace clips. If trunk
is still active but unable to place calls, refer problem to the CO .
140
This condition occurs when the CO starts dialing before the PBX
This condition occurs when the CO starts dialing too soon after seizure
This condition occurs when the CO sends rotary dial digits
More than 135 msec between two successive breaks.
Less than 75 msec between two successive breaks.
CO is starting new rotary dial digit within 150 msec of previous digit.
CO not releasing trunk after PBX disconnect. Occurs when the PBX
DID-TRK (Direct Inward Dial Trunk)
Break between rotary pulses is too long.