6 Avaya MultiVantage Software-Controlled Maintenance:
Table 80. DS1 Tie Trunk Maintenance Error Log Entries Continued
Error
Type
769(h)
1025
1793(i)
2305(j)
2562(k)
2817(l)
3840(m)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
***This alarm will only be raised when the System-Parameter Country form has the Base
Tone Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or
more trunks in this trunk group are out of service, then the alarm will be upgraded to a
MAJOR alarm.
****Major or Minor alarms on this MO may be downgraded to Warning alarms based on
the values used in the set options command.
Notes:
• (a) Error Type 1—The DS1 Interface Media Module detects a hardware error on the DS1 tie trunk.
This error can be caused by incompatible translations. Make sure the parameters administered on
the DS1 Media Module form match those administered on the far-end switch. See Administrator's
Guide for Avaya MultiVantage™ Software, 555-233-506, for details.
The Aux Data field indicates the following hardware error types:
If all administration errors between the switch and the far-end match, and these errors continue to
recur, follow normal escalation procedures.
• (b) Error Type 15—This is a software audit error that does not indicate any hardware malfunction.
Run Short Test Sequence and investigate associated errors (if any).
246
Aux
Associated Test
Data
57393
DS1 Tie Trunk
Seizure Test (#136)
DS1 Tie Trunk
Seizure (Test #136)
50944
DS1 Tie Trunk
Seizure Test (#136)
16665
52992
Any
Port Audit and
Update (Test #36)
57476
On-hook before wink
57477
On-hook before ready to receive digits
57485
Wink too short for valid signal
57487
The timer expired while waiting for an off-hook
signal from the far end as a response at end of
digits dialing. Check the far-end switch for related
problems.
TIE-DS1 (DS1 Tie Trunk)
Alarm
On/Off
Level
Board
MIN/MAJ
MIN/
OFF
WRN ***
MIN/MAJ
OFF
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test to Clear Value
test trunk grp/mbr r
2
test board
GGGVSpp long