4 Media Server Alarms:
Table 17. Alarm #10
Number
Source
Event ID
Alarm Level
Alarm Text Description
Possible Causes
Determining Cause
Resolution
Table 18. Alarm #11
Number
Source
Event ID
Alarm Level
Alarm Text Description
Possible Causes
Determining Cause
Resolution
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
10
_WD
7
Major
Cannot open exe using config file PID
Watchdog has a bad path name for an application it is
supposed to start.
Go to the Web Interface; choose Diagnostics; View System
Logs; select Watchdog Logs
1. Verify that the file named in the log exists and is
executable.
2. Verify that the string in watchd.conf is correct.
3. From the Web Interface, choose Alarms and Notification;
select the appropriate alarm; choose Clear
11
_WD
15
Major
Detected a rolling reboot
Watchdog has detected x number of Linux reboots within y
minutes, where x and y are configurable in
/etc/opt/ecs/watchd.conf. A variety of bad things could have
happened to cause a rolling reboot, it's not possible to list
them all.
Go to the Web Interface; choose Diagnostics; View System
Logs; select Watchdog Logs
1. (Lab only) Make sure all the executables listed in the
watchd.conf exist and are executable. It has been found that
the most common cause for rolling reboot is that files are not
where they are expected
2. If everything looks OK with step 1, further investigation of
trace log is necessary.
S8300 Alarms--_WD