6 Avaya MultiVantage Software-Controlled Maintenance:
Table 35. ISDN-PRI Signaling Group Error Log Entries Continued
Error
Type
257 (b)
513 (c)
769
1025
1793 (d)
2049 (e)
2305 (f)
3585 (g)
3842 to
3942(h)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
Notes:
• (a) This switch sent a message to the far-end switch or terminal adapter, and the far-end did not
respond in the allotted time. Possible causes include link failure and congestion or outage at the far-
end. The Aux Data field contains Layer 3 protocol information used by internal counters.
If no other symptoms are present, no action is required. If Layer 3 communication is down, there
should be indications in the form of alarms and errors for link components. Check out other errors
against ISDN-SGR, ISDN-TRK, and other hardware components on the link.
There is no test to clear these errors. The error counter is decremented by 1 every 15 minutes.
• (b) This error indicates that the primary signaling channel connection has been lost for more than
90 seconds. If a secondary signaling channel does not exist or is not in-service, the associated B-
channels will be placed in the ISDN Maintenance/Far-End state. The B-channels will not be usable
for outgoing calls, although incoming calls will still be accepted. The switch will automatically
attempt to recover the signaling link. Pay particular attention to the results of Test #636 (Primary
Signaling Link Hardware Check) in the test sequence. When the link does recover, the B-channels
will be negotiated back to the In-Service state and their alarms will be retired.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Aux
Associated Test
Data
Any
None
Any
None
Any
Primary Signaling Link
Hardware Check
(#636)
Any
Secondary Signaling
Link Hardware Check
(#639)
Any
Layer 2 Status (Test
#647)
Any
Layer 2 Status (Test
#647)
Any
Remote Layer 3 Query
(Test #637)
Port
None
number
Port
None
number
ISDN-SGR (ISDN-PRI Signaling Group)
Alarm
On/Off
Level
Board
WARNIN
OFF
G
WARNIN
OFF
G
MINOR
OFF
Test to Clear
Value
test sig-group
grp#
test sig-group
grp#
test sig-group
grp#
test sig-group
grp#
test sig-group
grp#
test sig-group
grp#
test sig-group
grp#
2 of 2
167

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents