Avaya G700 Maintenance Manual page 130

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 6. TEST #3 CO Demand Diagnostic Test Continued
Error
Test
Code
Result
1004
ABORT
1005
ABORT
1018
ABORT
2000
ABORT
FAIL
130
Description/ Recommendation
The port was seized by a user for a valid call.
Use the display port GGGVSpp command to determine the trunk
group/member number of the port. Use the status trunk command
to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before retesting.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
Test inapplicable to present configuration. This is a normal condition.
Test has been disabled via administration.
For this test to run, the Maintenance Tests? field on the trunk
group form must be set to n. The form is accessed with the change
trunk-group grp# command.
Response to the test was not received within the allowable time
period.
Retry the command at 1-minute intervals for a maximum of 5 times.
Failure to detect ground or faulty ground detected on Ring lead.
Display the hardware errors for this trunk, to determine if the fault
was on- or-off board. Look for Error Type 1025 or 1281 (if both
appear in the Hardware Error Log, pick the most recent error). Error
Type 1025 indicates a faulty ground detected on Ring lead (an off-
board fault) and Error Type 1281 indicates failure to detect (internally
generated) ground (an on-board fault).
Faulty ground detected on Ring lead (Error Type 1025):
Repeat test. If test passes, ignore the original failure. If test aborts,
follow the recommended procedures.
Repeat test with CO line removed.
If test fails, replace the Media Module.
If test passes, refer problem to CO .
Failure to detect ground (Error Type 1281):
Run the long test sequence. If the CO Demand Diagnostic Test fails,
the Dial Tone Test (#0) fails with Error Code 2002, AND Error Type
3329 or 3585 appears in the Hardware Error Log (with the same last
occurred time as Error Type 1281 and 1537), replace the Media
Module.
Repeat test with CO line removed.
If test fails, replace the Media Module.
If test passes, the CO may be drawing too much current. Refer
problem to CO .
CO-TRK (Analog CO Trunk)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
2 of 3