6 Avaya MultiVantage Software-Controlled Maintenance:
Table 46. System Technician-Demanded Tests: DS1-MM
Order of Investigation
NPE Crosstalk Test (#6)
Note: This Test ABORTS when run on
a Avaya G700 Media Gateway system.
Conference Circuit Test (#7)
Note: This Test ABORTS when run on
a Avaya G700 Media Gateway system.

Audit and Update Test (#36)

Signaling Link State Check Test (#255)
Service State Audit Test (#256)
Call State Audit Test (#257)
ISDN Test Call Test (#258)
Note: This Test ABORTS when run on
a Avaya G700 Media Gateway system.
D = Destructive, ND = Non-destructive
*
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 interface Media Module
to assure that the trunk's translation is correct. The port audit operation verifies the consistency of the
current state of trunk kept in the DS1 interface Media Module and in the switch software.
Table 47. TEST #36 Audit and Update Test
Error
Test
Code
Result
1018
ABORT
ABORT
2000
ABORT
2100
ABORT
FAIL
186
Short Test
Sequence
X
X
X
X
Description/ Recommendation
Maintenance is disabled on this trunk.
Enable maintenance by entering "y" in the "Maintenance Tests?" field
on page 2 of the change trunk-group form.
Internal system error
Response to the test request was not received within the allowable
time period.
Could not allocate the necessary system resources to run this test.
Test failed due to internal system error.
Retry the command at 1-minute intervals for a maximum of 5 times.
ISDN-TRK (DS1 ISDN Trunk)
Long Test
Sequence
X
X
X
X
X
X
X
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
D/ND*
ND
ND
ND
ND
ND
ND
ND