6 Avaya MultiVantage Software-Controlled Maintenance:
Table 66. TEST #139 Blue Alarm Inquiry Test Continued
Error
Code
1
1794
1795
Any
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
FAIL
The remote DS1 endpoint is out-of-service.
FAIL
The DS1-MM Interface Media Module detects a Line Loopback
Alarm (LLB).
If the DS1-M interface Media Module connects to a T1 facility, call
the vendor of the T1 carrier to diagnose the remote DS1 endpoint.
If the DS1-mm interface Media Module connects directly to a switch,
call the system technician of the remote switch to diagnose the DS1
endpoint.
If theDS1-MM interface Media Module connects directly to a line-
side terminating device (for example, a PRI terminal adapter), call
the vendor of the terminating device to diagnose the equipment.
FAIL
The DS1-MM Interface Media Module detects a Payload Loopback
Alarm (PLB). If the DS1-MM Interface Media Module connects to a
leased T1 facility, call the vendor of the T1 carrier to diagnose the
remote DS1 endpoint. If the DS1-MM Interface Media Module
connects directly to another DS1 board, call the system technician of
the remote switch to diagnose the DS1 endpoint. If the DS1-MM
Interface Media Module connects directly to a line-side terminating
device such as a PRI terminal adapter contact the vendor of the
terminating device to diagnose the equipment.
PASS
Remote DS1 endpoint is in-service. Neither a Blue alarm nor a Line
Loopback alarm nor a Payload Loopback Alarm is detected by the
DS1-MM Interface Media Module.
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the MM-DS1 interface if it is not
already administered.
If the board was already administered correctly, check the error log
to determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue
the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the
port.