6 Avaya MultiVantage Software-Controlled Maintenance:
Table 83. TEST #136 DS1 Tie Trunk Seizure Test
Error
Code
1000
1004
1005
1018
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
ABORT
System resources required to run this test were not available. The
port may be busy with a valid call.
Use the display port GGGVSpp command to determine the trunk
group/member number of the port. Use the status trunk
command to determine the service state of the port. If the port is
in use, wait until the port is idle before testing.
If the port status is active but the port is not in use (no calls),
check the error log for error type 1025 (see the error log table for a
description of this error and required actions). The port may be
locked up.
If the port status is idle, retry the command at 1-minute intervals
for a maximum of 5 times.
ABORT
Far end is seizing the trunk while the test is ongoing. A glare
situation is detected. Current test is designed to be aborted.
Use the display port GGGVSpp command to determine the trunk
group/member number of the port. Use the status trunk
command to determine the service state of the port. If the port is
in use, wait until the port is idle before testing.
If the port status is idle, retry the command at 1-minute intervals
for a maximum of 5 times.
ABORT
Test failed due to incompatible configuration administered in trunk
group form.
Verify the following fields on the trunk group administration
screen:
Is trunk direction incoming only?
Is trunk outgoing type either automatic or immediate-start?
Is trunk the 24th port of the DS1 Interface Media Module while
common control channel signaling is specified?
If the trunk has been administered using the above information,
then this test should abort.
ABORT
The test was disabled via translation. You may want to determine
why the test has been disabled before you enable it.
Verify that the 'Maintenance Test' field on the 'Trunk
Administration' screen is set to 'n.' To enable the test, change the
trunk administration and enter 'y' into the 'Maintenance Test' field.
Repeat the test.
TIE-DS1 (DS1 Tie Trunk)
1 of 3
251