Avaya G700 Maintenance Manual page 119

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 60. TEST #36 Port Audit and Update Test Continued
Error
Code
Any
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
NO
The test could not relate the internal ID to the port. This result could
BOARD
be due to incorrect translations, no board inserted, an incorrect
board inserted, an insane board inserted, or the board is
hyperactive.
Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the
port. If not, to check that there is a valid board inserted.
Hyperactivity causes some special problems with the sequence
suggested above. If the ports are translated after issuing the list
config command but the 'Vintage' field reports that there is no
board (when there really is a board), then the busyout board and
the release busy board commands do not work (even though the
reset board command does work). The software puts the
hyperactive board back in service after the hyperactivity clears.
CO-DS1 (DS1 CO Trunk)
2 of 2
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents