Port Diagnostic Test (#35) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

Port Diagnostic Test (#35)

This test checks a port's battery feed circuitry for on-/off-hook detection, battery shutdown, and
battery reversal (wink) capabilities.
Table 15. TEST #35 Port Diagnostic Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
142
Description/ Recommendation
System resources required to run this test were not available.
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test were not available. The
port may be busy with a valid call.
Enter display port GGGVSpp command to determine the trunk
group/member number of the port. Use the status trunk command
to determine the service state of the port. If the port is in use, wait
until the port is idle before testing.
If the port status is active but the port is not in use (no calls), check
the error log for Error Type 513. The port may be locked up.
If the port status is idle, busyout and release the trunk, and retry the
command at 1-minute intervals a maximum of 5 times.
If the test continues to abort, check for wiring errors toward the CO
which may cause the trunk to lock up.
If the wiring is good and the test continues to abort, replace the circuit
pack.
The port was seized by a valid call during the test.
Enter display port GGGVSpp to determine the station extension,
attendant number, or trunk group/member number of the port. Use
the status station , status attendant , or status trunk command to
determine the service state of the port. If the port is in use, wait until
the port is idle before testing. Attendants are always in use (off-hook)
if the handset is plugged in and the port is not busied out.
Retry the command at 1-minute intervals a maximum of 5 times.
Test disabled via administration. Verify that the Maintenance
Tests? field on the Trunk Group Form is set to n. To enable the test,
issue the change trunk-group x command (x is the trunk group
number). Then change the entry in the Maintenance Tests? field
to y .
Response to the test was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.