Saki Sanity Test (#53) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

SAKI Sanity Test (#53)

!
CAUTION:
Table 64. Test #53 SAKI Sanity Test
Error
Code
None
1005
1015
2100
1
2
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
This test resets the Media Module. The test is highly destructive and can only
be initiated by a system technician-demanded reset board GGGVS command.
Test
Description/ Recommendation
Result
ABORT
System resources required for this test are not available.
Retry the reset board command at 1-minute intervals a maximum of
5 times.
ABORT
Wrong Media Module configuration to run this test. This error applies
only to DS1 Interface Media Modules. It means the DS1 Interface
Media Module is providing timing for the system, and therefore, it
cannot be reset without major system disruptions.
If the Media Module needs to be reset, then set synchronization to
another DS1 Interface Media Module or to the Tone-Clock Media
Module and try again.
ABORT
Port is not out-of-service.
Busyout the Media Module.
Execute the reset board command again.
ABORT
System resources required for this test are not available.
Retry the reset board command at 1-minute intervals a maximum of
5 times.
FAIL
The Media Module failed to reset.
FAIL
The Media Module failed to restart.
Execute the reset board command again.
If the problem persists, replace the Media Module.
PASS
The Media Module initializes correctly.
Run the Short Test Sequence.
MG-DS1 (DS1 Interface Media Module)