Avaya G700 Maintenance Manual page 303

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

Table 119. Tests Not Executed on the G700 Platform
Test
NPE_AUDIT
DS1_DTONE_TS
NEON_TEST
CLK_HEALTH
TDM_NPE_XTALK
CONF_TEST
MOD16_LOOP
GPP_LP
GPP_NPE
FT_GPP_LOOP
FT_LOOP
ICSU_LEDS
DIAL_TONE_TS
TRK_AUTO_GRD
TRK_PPM_TEST
TRK_HYB_TS
ONS_HYB_TS
BRI_EPF
L1_INQ
SSP_TDMLOOP
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
A DEFINITY Server-Controlled Maintenance: Testing
Notes
This test is really an audit that sends network update messages
to various ports on a board. Since the DEFINITY server does not
handle network connections for the MG, this test is not run.
DS1 CO trunk dial tone seizure test
This is run only for those boards that support the neon message
lamp. Therefore, it is not needed for R1.
Reads the LMM loss-of-clock status bits for the specified tone
clock board
Checks if the NPE chip is transmitting on more than one
timeslot. Since timeslots are not under the DEFINITY server's
control, this test will not be run.
Tests the conference circuit in the NPE. Needs the use of
Timeslots; therefore, this test is not run.
A 1004Hz reflective analog loop around on an analog port. This
test requires the use of a tone detector and all TDs are under
control of the MG.
GPP internal loopback tests is sent through both the I and S
channels for a port. A tone detector is needed to detect and
report the test pattern.
The GPP NPE xtalk test. The DEFINITY server does not handle
network connections, so this test is not run.
Factory external loop around test for the GPP board.
Factory external loop around test for almost all boards.
Checks the Integrated Channel Service Unit LEDs, which do not
exist on the DS1 Media Module.
Detects dial tone.
This test is for the Australian version of the CO board, TN438.
Factory only test for certain CO trunks; requires a pulse
generator.
Tests the loop around capabilities of a port's codec and hybrid
circuits.
Tests the loop around capability on the codec circuit.
Electronic power feed test; not valid for TN2185.
This function actually encompasses several tests.
This is for the messaging angel, but the DEFINITY server is
unaware of the TDM bus.
303

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents