6 Avaya MultiVantage Software-Controlled Maintenance:
Table 15. TEST #35 Port Diagnostic Test Continued
Error
Test
Code
Result
6144
FAIL
6
6145
FAIL
6
6147
FAIL
2
PASS
Any
NO
BOARD
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Description/ Recommendation
Battery feed test failed. A loop current fault was detected. This is
most probably an incoming CO-line problem. This failure code is only
reported by the TN2139 Italian DID Media Module.
Check the incoming CO-line for loop current. If none is detected refer
the problem to the CO .
If the CO-line checks out OK, the failure must be on the DID port.
Replace the Media Module.
Battery feed test failed. An on-board problem was detected. This port
is out-of-service.
Replace Media Module.
Battery feed test failed. A problem with the incoming CO-line was
detected.
Check the incoming CO-line for proper operation. If warranted, refer
the problem to the CO .
If the CO-line is not at fault, the failure must be on the DID port.
Replace the Media Module.
Current flow was detected for this port.
User-reported troubles on this port should be investigated using
other port tests and by examining connections.
Refer problem to the CO .
The test could not relate the internal ID to the port (no board).
Check to ensure that the board translations are correct. Translate the
board, if necessary.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
If the problem persists, replace the circuit pack.