Error Log Entries And Test To Clear Values - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

Error Log Entries and Test to Clear Values

Table 20. Digital Line Error Log Entries
Error
Type
0*
1 (a)
1 (b)
18 (c)
130 (d)
257 (e)
513
767 (f)
769 (g)
1026(o)
1281
1537 (h)
2304 (n)
2305 (i)
2305 (h)
2817(j)
3840 (k)
3840 (l)
3841 (m)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
**Major alarms may be downgraded to Warning alarms based on the value used in the
set options command.
Notes:
150
Aux
Associated
Data
Test
0
Any
40987
None
1 to 20
None
0
busyout port
GGGVSpp
None
40971
None
0
Station (Digital)
Audits Test
(#17)
40964
None
40963
None
40988
NONE
Any
Station (Digital)
Audits Test
(#17)
40968
None
None
32770
None
40967
None
Any
None
40965
None
40989
None
41029
None
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
ON
WARNING
OFF
(o)
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
OFF
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
DIG-LINE (Digital Line)
Test to Clear Value
test port GGGVSpp sh
r 1
rel port GGGVSpp
test port GGGVSpp sh
test port GGGVSpp sh
r 6
test port GGGVSpp sh
r 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents