6 Avaya MultiVantage Software-Controlled Maintenance:
Table 54. TEST #36 Station Status and Translation Audits and Updates Continued
Error
Code
1005
1006
2000
2100
1
5
7
8
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
This test was aborted due to a configuration problem. The test is
not applicable for this type of analog port. This error can be
ignored.
ABORT
The port is out-of-service. The busy station extension command
has been given to this port.
Look for error type 18 (port busied out) for this port. If this error is
present, release the port ( release station extension), and run the
test again.
Make sure that the terminal is connected and in service, and then
retest.
ABORT
Response to the test request was not received within the allowable
time period.
ABORT
System resources required to run this test are not available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
FAIL
The switchhook audit failed. This result does not indicate a
hardware problem. The other updates were not performed
because of this failure. This may occur if the audit is performed at
the same time the terminal equipment goes off-hook.
Use the status station extension command to determine when
the port is available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to fail, escalate the problem.
FAIL
The message waiting lamp update failed. This may be an internal
software error. The translation and ringer updates were not
performed because of this failure.
FAIL
The translation update failed. There may be an internal software
error. The ringer update was not performed because of this failure.
FAIL
The ringer update failed. There may be an internal software error.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to fail, escalate the problem.
PASS
The software and the port processor have the same status.
Investigate user-reported troubles on this port by running other
port tests, by examining station wiring, or by inspecting the station.
AN-LN-PT (Analog Line Port)