6 Avaya MultiVantage Software-Controlled Maintenance:
Table 7. TEST #36 Port Audit Update Test Continued
Error
Test
Code
Result
FAIL
PASS
Any
NO
BOARD
132
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals for a maximum of 5 times.
This test passed. Translation information was successfully updated
on the Media Module. User-reported troubles on this port should be
investigated by using other port tests and by examining trunk or
external wiring. If the trunk is busied out, the test will not run, but will
return PASS. To verify that the trunk is in-service:
Enter status trunk to verify that the trunk is in-service. If the trunk is
in-service, no further action is necessary. If the trunk is out-of-
service, continue to Step 2.
Enter release trunk command to put trunk back into in-service.
Retry the test command.
The test could not relate the internal ID to the port (no board).
Check to ensure that the board translations are correct. Translate
the board, if necessary.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
CO-TRK (Analog CO Trunk)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
2 of 2