6 Avaya MultiVantage Software-Controlled Maintenance:
• (i) Error Type 2562—Retry Failure error. This error is logged only. It is not a hardware failure and
hence does not start any testing or generate any alarms. This error comes from call processing and
is generated when a second attempt (retry) to seize an outgoing trunk fails.
• (j) Error Type 2817—Glare error. This error is logged only. It is not a hardware failure and hence
does not start any testing or generate any alarms. This error is the result of a simultaneous seizure
of a two-way trunk from both the near-end and the far-end. Attempt to place the call again. If the
error persists, escalate.
• (k) Error Type 3840—Port Audit and Update Test (#36) failed due to an internal system error.
Enter the status trunk command to verify the status of the trunk. If the trunk is out-of-service,
then enter the release trunk command to put it back into in-service. Retry the test command.
System Technician-Demanded Tests:
Descriptions and Error Codes
!
CAUTION:
.
Table 59. Order of Investigation
Order of Investigation
NPE Crosstalk Test (#6)
Note: This Test ABORTS
Conference Circuit Test (#7)
Note: This Test ABORTS
DS1 CO Trunk Seizure Test (#314)
Note: This Test ABORTS

Port Audit and Update Test (#36)

*D = Destructive; ND = Nondestructive
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 Interface Media Module
to assure that the trunk's translation is correct. Translation updates include the following data: trunk
type (in/out), dial type, timing parameters, and signaling bits enabled. The port audit operation
verifies the consistency of the current state of trunk.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the NPE
Crosstalk Test, for example, you may also clear errors generated from other
tests in the testing sequence.
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
CO-DS1 (DS1 CO Trunk)
D/ND*
ND
ND
ND
ND