6 Avaya MultiVantage Software-Controlled Maintenance:
Table 83. TEST #136 DS1 Tie Trunk Seizure Test Continued
Error
Test
Code
Result
1020
ABORT
1040
ABORT
2000
ABORT
2053
ABORT/
FAIL
2100
ABORT
FAIL
252
Description/ Recommendation
The test did not run due to an already existing error on the specific
port or due to a more general Media Module error.
Examine the error log for existing errors against this port or the
Media Module and attempt to diagnose the already existing error.
Retry the test.
The test is invalid for this trunk port because it is administered as
an access endpoint.
Use display port to verify that this port is administered as an
access endpoint. In this case the test should abort.
Response to the test request was not received within the
allowable time period.
Retry the command at 1-minute intervals for a maximum of 5
times.
At least one of the following errors is found on the DS1 Media
Module: 1281: Loss of Signal 1793: Blue Alarm 2049: Red Alarm
*
2305: Yellow Alarm 1537: Hyperactivity
Look for the above error types in the Hardware Error Log and
follow the procedures given in the appropriate DS1-BD/MM-DS1-
BD Maintenance documentation for the listed error types.
Could not allocate the necessary system resources to run this
test.
Retry the command at 1-minute intervals for a maximum of 5
times.
The far-end trunk did not respond to the seizure of the near-end
trunk within the allowable time period. This test could have
associated in-line errors in the error log.
Enter the list configuration board GGGVS command.
Eventually, the board and all of its ports will be taken out of
service and extraneous on-board alarms will be generated.
Replace the Media Module with a TN767C V3 or later.
Verify that the 'Trunk Type' field on the 'Trunk Administration'
screen matches the trunk type administered on far-end switch.
Look for DS1-BD or MM-DS1 errors in the hardware error log. If
present, refer to the DS1-BD (DS1 trunk Media Module)
Maintenance documentation or to the MM-DS1 (MM-DS1 trunk
Media Module) Maintenance documentation.
Retry the test at 1-minute intervals for a maximum of 5 times.
TIE-DS1 (DS1 Tie Trunk)