Alarm-Pt (Alarm Port); Error Log Entries And Test To Clear Values - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

ALARM-PT (ALARM PORT)

Table 45. ALARM-PT (ALARM PORT)
MO Name (in Alarm
Log)
ALARM-PT
ALARM-PT
Note: You must consult local records for the location and designation of the equipment
rack where the G700 is mounted.
The Alarm Port MO provides on-board maintenance for an analog line port that is administered as an
external device alarm port. Test are provided to verify the analog line ports ability to detect an
external device alarm. The external device alarm (EXT-DEV) MO is used for the off-board external
device alarm.

Error Log Entries and Test to Clear Values

Table 46. 8-Port Analog Line Error Log Entries
Error
Type
0*
15 (a)
18
130 (b)
769
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to
the appropriate test description and follow the recommended procedures
Notes:
(a) This is a software audit error that does not indicate any hardware malfunction. Run
Short Test SeSquence and investigate errors.
(b) Indicates that the Media Module has been removed or has been insane for more than
11-minutes. To clear the error, reseat or replace the Media Module.
102
Alarm
Level
MIN
WRN
Aux
Associated
Data
Test
0
Any
Any
Audits and
Updates Test
(#36)
0
busy-out
station
extension
None
Battery Feed
Test (#35)
Initial Command to Run
test port GGGVSPP l
test port GGGVSPP sh
Alarm
On/Off
Level
Board
Any
Any
WARNIN
OFF
G
WARNIN
ON
G
MINOR
ON
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
ALARM-PT (ALARM PORT)
Full Name of MO
Alarm-Port
Alarm-Port
Test to Clear Value
test port GGGVSpp sh r 1
release station extension
test port GGGVSpp sh
test port GGGVSpp sh r 2