6 Avaya MultiVantage Software-Controlled Maintenance:
Table 69. TEST #142 Major Alarm Inquiry Test Continued
Error
Code
Any
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
FAIL
If the DS1-MM connects to a line-side terminating device (for
(cont'd.)
example, a PRI terminal adapter), do the following:
The performance of the DS1 link between the DS1-MM interface
Media Module and the line-side terminating device is very poor.
Enter the list measurement ds1-log GGGVS command to read
the error seconds measurement.
Verify that the switch DS1 and the line-side terminating device
are administered using the same signaling mode, framing mode,
and line coding.
Investigate the maintenance status of the line-side terminating
device. Refer to the 'Line-Side Terminating Device Operating
Manual' for information.
Contact the vendor of the line-side terminating device to
diagnose the equipment.
Check the physical connection of the DS1-MM1 interface Media
Module to the terminating device, and check the premise
distribution system (or the intra-premise wiring) for physical
connection failures.
Replace the local DS1-MM interface Media Module and repeat
the test.
PASS
No Major alarm is detected in the DS1-MM Interface Media Module.
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the MM-DS1 interface if it is not
already administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue
the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the
port.