4 Media Server Alarms:
Table 19. Alarm #12
Number
Source
Event ID
Alarm Level
Alarm Text Description
Possible Causes
Determining Cause
Resolution
Table 20. Alarm #13
Number
Source
Event ID
Alarm Level
Alarm Text Description
Possible Causes
Determining Cause
Resolution
62
12
_WD
18
Warning
Application Restarted
An application has failed and watchdog has restarted it
successfully.
Go to the Web Interface; choose Diagnostics; View System
Logs; select Watchdog Logs
From the Web Interface, choose Alarms and Notification;
select the appropriate alarm; choose Clear
13
_WD
19
Minor
Application failed unintentionally
Watchdog is bringing the system down because an
application has failed to start correctly. The application may
have failed to start because the file did not exist (coincident
with 7), or required parameters for the application in
watchd.conf were missing or invalid.
Go to the Web Interface; choose Diagnostics; View System
Logs; select Watchdog Logs
1. Verify that the file named in the log exists and is
executable.
2. Verify that the string in watchd.conf is correct.
3. From the Web Interface, choose Alarms and Notification;
select the appropriate alarm; choose Clear
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
S8300 Alarms--_WD