SREPN Maintenance
Fault isolation procedures
13. Did the test return Board not inserted for the near-end circuit pack
(nearest the SPE), or for the far-end circuit pack in a simplex PNC?
14. If No , visually check to see if any CSU devices are looped back.
15. Did Test #788 pass and Test #789 fail?
16. If No , did Test #788 fail or abort and Test #789 fail or abort?

Loopback tests

The following section describes loopback tests:
''Fiber direct-connect system''
''DS1 CONV system''
''Manual loopback procedure''
a. If Yes , replace the cabling between the DS1C circuit pack and the
SNI or EI circuit pack.
b. Wait 1 minute and retest.
c. If the board is still not inserted, replace the DS1C circuit pack and
the EI or SNI connected to it and Go back to Step 12 in the
information''
procedure above.
a. Busyout the circuit pack (busyout board UUCSS).
b. Test for external loopback (test ds1-facility UUCSS external-loop)
for each DS1 facility.
NOTE:
Many tests pass if the system is in Survive mode.
a. If yes, replace the DS1C and lightwave transceiver (if present) at the
other end of the DS1C complex. (See
b. Go back to Step 12 in the
a. If Yes , enter test ds1-facility UUCSS long for each administered
and equipped DS1 facility.
NOTE:
If the Switch Node Interface (SNI) board's yellow LED is fast flashing
(0.1 sec on/0.1 sec off), it can indicate a problem with the fiber from
the SNI board to the SREPN. For more detailed information, refer to
the SNI-BD Maintenance Object in Chapter 9 of DEFINITY ECS
Release 9 Maintenance for R9r .