System Technician-Demanded Tests: Descriptions And Error Codes; Port Audit And Update Test (#36) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting errors in the
system. By clearing error codes associated with the NPE Crosstalk Test, for example, you may also
clear errors generated from other tests in the testing sequence.
Table 81. System Technician-Demanded Tests
Order of Investigation
NPE Crosstalk Test (#6)
Note: This Test will abort with Error
Code 1412
Conference Circuit Test (#7)
Note: This Test will abort with Error
Code 1412
DS1 Tie Trunk Seizure Test (#136)

Port Audit and Update Test (#36)

*D = Destructive; ND = Nondestructive
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 Interface Media Module
to ensure that the trunk's translation is correct. Translation updates include the following data: trunk
type (in/out), dial type, timing parameters, and signaling bits enabled. The port audit operation
verifies the consistency of the current state of the trunk kept by the DS1 Interface Media Module and
the switch software.
Table 82. TEST #36 Audit and Update Test
Error
Test
Code
Result
ABORT
248
Short Test
Sequence
X
X
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
TIE-DS1 (DS1 Tie Trunk)
Long Test
Sequence
X
X
X
X
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
D/ND*
ND
ND
ND
ND
1 of 3