Port Audit And Update Test (#36) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

Port Audit and Update Test (#36)

This test sends port level translation data from the switch processor to the DS1 Interface Media
Module to assure that the trunk's translation is correct. The port audit operation verifies the
consistency of the current state of the trunk as kept in the DS1 Interface Media Module and in the
switch software.
Table 11. TEST #36 Port Audit and Update Test
Error
Test
Code
Result
ABORT
1000
ABORT
1006
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
136
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
The port may be busy with a valid call.
Issue display port GGGVSpp to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
If the port status is active but the port is not in use (no calls), check
the error log for error type 1025. The port may be locked up.
If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
The test was aborted because the trunk is out of service.
Use status trunk to verify that the trunk is out of service.
If the trunk is out of service, determine why.
To put the trunk back in service, issue the release trunk command.
Retry the test.
Response to the test was not received in the allowable time period.
Could not allocate resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
Test failed due to internal system error.
Retry the command at 1-minute intervals a maximum of 5 times.
Trunk translation has been updated successfully. The current trunk
states kept in the DS1 Interface Media Module and switch software
are consistent. If the trunk is busied out, the test will not run but will
return PASS. To verify that the trunk is in-service:
Enter status trunk to verify that the trunk is in-service. If the trunk is
in-service, no further action is necessary. If the trunk is out-of-
service.
Enter release trunk to put the trunk back into in-service.
Retry the test command.
DID-DS1 (Direct Inward Dial Trunk)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
1 of 2