System Technician-Demanded Tests: Descriptions And Error Codes; Mg-Ann (Voice Announcements); Voice Announcements Over The Lan - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
System Technician-Demanded Tests:
Descriptions and Error Codes
!
CAUTION:
Table 55. Order of Investigation
Order of Investigation
NPE Audit Test (#50)
Note: This test will abort with Error
Code 1412.
Ringing Application Test (#51)
Aborts with code 1412
Control Channel Looparound Test
(#52)
SAKI Sanity Test (#53)
NEON Test (#220)
Aborts with code 1412
D = Destructive; ND = Nondestructive
*
For hardware error log entries and for more information on the tests listed in the table above refer to
" MO XXX-BD (common port Media Module)" maintenance object documentation.

MG-ANN (Voice Announcements)

Voice Announcements over the LAN

The ANN-VMM (Voice Announcements) maintenance object provides per board announcement
storage time of up to 20 minutes, (15 playback ports and 1 recording port that can also be used as a
playback port) and allows for announcement file portability via LAN connectivity. ANN-VMM also
allows for LAN backup and restore of announcement files and the use of customer provided
waveform (.WAV) files.
194
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the NPE
Crosstalk Test, for example, you may also clear errors generated from other
tests in the testing sequence.
MG-ANN (Voice Announcements)
Short Test
Long Test
Sequence
Sequence
X
X
X
X
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Reset
D/ND*
Board
Sequence
ND
ND
D