6 Avaya MultiVantage Software-Controlled Maintenance:
Table 28. Order of Investigation
Order of Investigation
Dial Tone Test (#0)
Note: This Test will abort with Error Code
1412
Looparound and Conference Test (#33)
Note: This Test will abort with Error Code
1412
Audit Update Test (#36)
*D = Destructive; ND = Nondestructive

Port Audit Update Test (#36)

This test sends updates of the CO port translation for all ports on the Media Module which have been
translated. The update is non-disruptive and guards against possible corruption of translation data
contained on the Media Module. No response message is expected from the Media Module once it
receives translation updates. The port translation data includes: ground or loop start trunk, tone or
rotary dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect timing.
Table 29. TEST #36 Port Audit Update Test
Error
Code
2100
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
ABORT
Could not allocate the necessary system resources to run the test.
FAIL
Internal system error.
Retry the command at 1-minute intervals a maximum of 5 times.
PASS
This test passed. Translation information was successfully updated
on the Media Module. User-reported troubles on this port should be
investigated by using other port tests and by examining trunk or
external wiring. If the trunk is busied out, the test does not run, but
returns PASS. To verify that the trunk is in-service:
Enter status-command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is out-
of-service, continue to Step 2.
Enter release-trunk command to put trunk back into in-service.
Retry the test command.
DIOD-TRK (DIOD Trunk)
Short Test
Long Test
Sequence
Sequence
X
X
X
X
D/ND*
ND
ND
ND