6 Avaya MultiVantage Software-Controlled Maintenance:
• (d) Error Type 125: No Aux Data
An incorrect Media Module is inserted in the slot where the DS1-MM Media Module is logically
administered. To resolve this problem, either remove the incorrect Media Module and insert the
logically administered Media Module, OR use the change circuit-pack command to re-
administer this slot to match the Media Module inserted.
• (e) Error Type 257
This error is associated with the Common Port Media Module Maintenance Test. Refer to XXX-
BD (Common Port Media Module) Maintenance documentation for details.
• (f) Error Type 513
The DS1-MM (MM710) has detected a transient hardware problem. The value in the Aux Data
field indicates the type of hardware problem:
If the board detects only one of these hardware problems, then the error will disappear when none
of these faults are detected for 10 minutes. If the same Aux Data value is logged more than once
in a 24 hour period, the Media Module should be replaced.
• (g) Error Type 514
LAN External RAM Error. This error occurs when there is a hardware fault in the PPE external
RAM . The RAM is used for message buffering to and from the Packet Bus. This error should not
occur frequently. If it does (10 times within 30 minutes), the Media Module should be replaced.
• (h) Error Type 769
Transmit FIFO Underflow Error. This error occurs when the Media Module cannot find the end of
frame bit when transmitting a frame to the Packet Bus. An alarm is raised if this error occurs three
times within 10 minutes. Clear the alarm using the following commands: busyout board
GGGVS , reset board GGGVS , test board GGGVS long , release board GGGVS . If the
error recurs within 10 minutes, replace the Media Module.
• (i) Error Type 770
Unable to Write LAN Translation RAM Error. This error occurs when a call is aborted because
there are no available translation RAM locations for the call connection attempt. An alarm is
raised if this error occurs two times within 10 minutes. Clear the alarm using the following
commands: busyout board GGGVS , reset board GGGVS , test board GGGVS long ,
release board GGGVS . If the error recurs within 10 minutes, replace the Media Module.
• (j) Error Types 1400, 1401
Echo Cancellation errors are logged when:
- Error 1400 - Echo canceller function failed. The Echo Canceller Function Test, which is
executed by firmware, failed.
- Error 1401 - Echo canceller memory failed. The Echo Canceller Memory Test, which is
executed by firmware, failed.
206
Aux Data
Problem
4352
External RAM failure
4353
Internal RAM failure
4355
Internal ROM failure
MG-DS1 (DS1 Interface Media Module)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002