Control Channel Looparound Test (#52); Plat-Alm (Platform Alarms) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 77. System Technician-Demanded Tests
Order of Investigation
Control Channel Loop Test (#52)
*D = Destructive; ND = Nondestructive

Control Channel Looparound Test (#52)

This test queries the Media Module for its vintage to verify communication with the board.
Table 78. TEST #52 Control Channel Looparound Test
Error
Code
None
2100
0

PLAT-ALM (Platform Alarms)

The PLAT_ALM is a virtual MO used by Avaya MultiVantage™ software to keep track of Media
Server alarms. A MAJOR, MINOR, or WARNING alarm can be logged against this MO to indicate
the presence of one or more Media Server alarms.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The Media Module failed to return the Media Module code or
vintage.
Retry the command a maximum of 5 times.
If the problem continues, replace the Media Module.
Retry the command.
PASS
Communication with this Media Module is successful.
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
If the board was found to be correctly inserted in step 1, then issue
the busyout board GGGVS command.
Issue the reset board GGGVS command.
Issue the release board GGGVS command.
Issue the test board GGGVS long command.
This should re-establish the linkage between the internal ID and the
port.
PLAT-ALM (Platform Alarms)
Short Test
Long Test
Sequence
Sequence
X
D/ND*
ND
243