6 Avaya MultiVantage Software-Controlled Maintenance:
MM711 trunk Media Modules provide eight ports for loop-start CO trunks.
Loop Start Operation
Idle State: Tip = ground, Ring = CO Battery
Outgoing Call
1 . PBX Off-Hook (Seize Message): Closes the Tip-Ring Loop CO Response: DC loop current +
Dial tone
2 . PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current CO Response: CO goes to
idle state (see Note)
Incoming Call
1 . CO Applies Ringing Voltage PBX Response: Detect ringing current
2 . PBX Off-Hook (Answer Message): Close loop CO Response: Trip ringing, provide loop current
3 . PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current CO Response: CO goes to
idle state (see Note)
Direct Inward Dialing (DID)
1 . CO Applies Ringing Voltage
- PBX Response: Detect ringing current and close loop
- CO Response: Send DTMF digits
- PBX Response: Acknowledge of Number dialed and open loop
2 . PBX Off-Hook (Answer Message): Close loop CO Response: Trip ringing, provide loop current
3 . PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current CO Response: CO goes to
idle state (see Note)
Note:
CO does not normally provide an On-Hook (Disconnect) signal.
158
DIOD-TRK (DIOD Trunk)
Maintenance for S8300/S8700 and G700