6 Avaya MultiVantage Software-Controlled Maintenance:
MO Test Commands
Each command is arranged according to a standard command syntax. For G700 systems: Where GGG is the
G700 Number, the character V indicates that this system is a G700, S is the slot number from 1 to 4, and PP
is the port number from 1 to 32.
Full test commands can be either short or long as indicated, and can be repeated several times. For example,
in:
test port GGGVSpp sh r 1
sh = short
r = repeat
1 = the number of times the test should be repeated.
Similarly, in:
test port GGGVSpp l r 2
l = long
r = repeat
2 = the number of times the test should be repeated.
Abort Code 1412
Tests that do not run on the G700 will abort with Abort Code 1412. Tests that abort are listed under each
MO, but are not described.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
MO Test Commands
101