3 G700 Traps and Alarms:
Table 5. G700 Alarms (SNMP Traps) to the Primary Media Server
Event
Trap
Alarm
ID
#
Level
2
4
MIN
3
6
MIN
38
Description / Recommendation
cmgPsuBriefFanFault — A G700's PSU fan has been operating at less
than 90% of its nominal speed for between 5 and 15 minutes. (This
may be an early warning of overheating.)
1. Verify there are faults in the system. Use the Avaya™ G700 Media
Gateway Processor (MGP) Command Line Interface (CLI)
command show faults to display any faults on the G700.
2. If there is a fan/temperature fault, check to see if the fans are
working and/or if there is sufficient space around the G700 for air
circulation.
3. Maintenance software monitors voltages applied to the Media
Modules and other components of the G700, and compares these
to the general power supply unit (PSU) status bit. If none of these
voltages are out of tolerance, but the PSU status indicates failure,
this generates the fan fault, which will be indicated in the show
faults command output. Replace the entire G700. Fans and the
PSU are not field replaceable.
cmgPsuProlongedFanFault — A G700's fan has been operating at less
than 90% of its nominal speed for >= 15 minutes. (This may be an
early warning of overheating.)
1. Verify there are faults in the system. Use the Avaya™ G700 Media
Gateway Processor (MGP) Command Line Interface (CLI)
command show faults to display any faults on the G700.
2. If there is a fan/temperature fault, check to see if the fans are
working and/or if there is sufficient space around the G700 for air
circulation.
3. Maintenance software monitors voltages applied to the Media
Modules and other components of the G700, and compares these
to the general power supply unit (PSU) status bit. If none of these
voltages are out of tolerance, but the PSU status indicates failure,
this generates the fan fault, which will be indicated in the show
faults command output. Replace the entire G700. Fans and the
PSU are not field replaceable.
Continued on next page
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002