Error Log Entries And Test To Clear Values - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

Error Log Entries and Test to Clear Values

Table 9. DID-DS1 Trunk Error Log Entries
Error
Type
0*
1(a)
15(b)
18(c)
130(d)
257(e)
513(f)
769(g)
1793(h)
2305(i)
3840(j)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to
the appropriate test description and follow the recommended procedures.
**This alarm will only be raised when the System-Parameter Country form has the Base
Tone Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or
more trunks in this trunk group are out of service, then the alarm will be upgraded to a
MAJOR alarm.
***Major alarms may be downgraded to Warning alarms based on the value used in the
set options command.
Notes:
• (a) Error Type 1— DS1 Interface Media Module detects a hardware error on the DS1 DID trunk.
The Aux Data field indicates the following:
Maintenance does not start any testing or generate any alarms in response to these errors.
• (b) Error Type 15—This is a software audit error that does not indicate any hardware malfunction.
Run Short Test Sequence and investigate errors (if any).
• (c) Error Type 18—The trunk has been taken out of service by a demand busyout. No calls can be
made on this trunk.
134
Aux
Associated Test
Data
0
Any
Any
Any
Port Audit and
Update Test (#36)
None
57474
57473
57392
57393
50944
None
Port Audit and
Update Test (#36)
57476
On-hook before wink
57477
On-hook before ready to receive digits
57485
Wink too short for valid signal
DID-DS1 (Direct Inward Dial Trunk)
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
MIN/MAJ**
MIN/MAJ**
MIN/MAJ**
OFF
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test to Clear Value
test trunk grp#/mbr#
release trunk
grp#/mbr#
test trunk grp#/mbr#
test board GGGVSpp

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents