Error Log Entries And Test To Clear Values - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

Error Log Entries and Test to Clear Values

Table 58. CO-DS1 Trunk Error Log Entries
Error
Type
0*
1(a)
1(a)
15(b)
18(c)
130(d)
769(g)
1793(h)
2562(i))
2817(j)
3840(k)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
**Major alarms MO may be downgraded to Warning alarms based on the value used in
the set options command.
Notes:
• (a) Error Type 1—Aux Data 57408
- Aux Data 57487
• (b) Error Type 15—This is a software audit error that does not indicate any hardware malfunction.
Run Short Test Sequence and investigate associated errors (if any).
• (c) Error Type 18—System Technician has busied out the trunk to the out-of-service state. No calls
can be made on this trunk except the Facility Access Test Call.
• (d) Error Type 130—This error type indicates that the Media Module has been removed or has
been insane for more than 11-minutes. To clear the error, reinsert or replace the Media Module.
• (g) Error Type 769—The DS1 Interface Media Module detects a hardware fault. The Aux Data
field contains the following error type:
• (h) Error Type 1793— DS1 Interface Media Module is out-of-service. Look for MG-DS1 errors in
the Hardware Error Log. Refer to the DS1 Trunk Media Module or MG-DS1 Media Module
Maintenance documentation for details.
116
Aux
Associated Test
Data
0
Any
57408
57487
Any
Port Audit and
Update Test (#36)
0
busyout trunk
<grp>/<mbr>
None
57484
16665
52992
Port Audit and
Update Test (#36)
PBX could not get "loop close" signal.
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
No tip ground is detected on an outgoing call.
57484, fault is detected on tip/ring.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
CO-DS1 (DS1 CO Trunk)
Test to Clear Value
test trunk <grp>/<mbr>
release trunk
<grp>/<mbr>
test trunk <grp>/<mbr>
test board GGGVSpp l

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300